Simulator - IoT v0.18.0

862669460113133 stopped

WT-400M · HTTP · every 10s · seq 3948 · template: — · dtm: YYYYMMDDHHMMSS · → http://nxtio.com:8080/2b77152a3d4ff61a4e/track

Manual emit — codes: PU · PF · CF:n · SF

Slaves (2)

sid stat gid CSV hdr label ⚡ Energy Meter (3-phase) interval
# FieldName Units FieldType Resolution Generator Min / Value / Start / Base Max / Rate / Pct
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
+ Add registers — count · name prefix · random value range

Resolution rounds emitted values: 0 = integer, 0.0 = 1dp, 0.00 = 2dp, 0.000 = 3dp, blank = no rounding. Data packets carry dtm in YYYYMMDDHHMMSS.

sid stat gid CSV hdr label ⚡ Water Management interval
# FieldName Units FieldType Resolution Generator Min / Value / Start / Base Max / Rate / Pct
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
+ Add registers — count · name prefix · random value range

Resolution rounds emitted values: 0 = integer, 0.0 = 1dp, 0.00 = 2dp, 0.000 = 3dp, blank = no rounding. Data packets carry dtm in YYYYMMDDHHMMSS.

+ Add slave

Advanced — stat / gid / CSV header / interval

📦 Install a sensor kit

One click adds several sensors as separate slaves — like a real integrated multi-sensor product talking on RS-485.

What's in each kit?
Cold Storage Station 3 slaves
Combined T+RH probe + Door switch + Compressor energy — 3 slaves that together monitor a refrigerated room.
  • sensor_temp_humidity — Room T+RH
  • sensor_door — Door switch
  • sensor_energy_1ph — Compressor energy
Pump House 4 slaves
Flow + Pressure + Tank-level + Pump-energy — the four readings you need for a booster-pump skid.
  • sensor_flow — Outflow meter
  • sensor_pressure — Discharge pressure
  • sensor_level — Tank level
  • sensor_energy_1ph — Pump energy
HVAC Room 2 slaves
Combined T+RH probe + AC energy — minimum kit for office / server-room HVAC.
  • sensor_temp_humidity — Room T+RH
  • sensor_energy_1ph — AC energy
Greenhouse 3 slaves
Combined T+RH probe + Irrigation tank level + Vent — the basics for a horticulture demo.
  • sensor_temp_humidity — Air T+RH
  • sensor_level — Irrigation tank
  • sensor_door — Vent / door
Boiler House 4 slaves
Pressure + Temperature + Flow + Energy — process monitoring around a steam boiler.
  • sensor_pressure — Boiler pressure
  • sensor_temp — Steam temperature
  • sensor_flow — Steam flow
  • sensor_energy_1ph — Boiler energy

Live preview + Test Emit — left: what the NEXT tick will send · right: what was ACTUALLY sent last time

packing = per_slave (one packet per slave) · HTTPhttp://nxtio.com:8080/2b77152a3d4ff61a4e/track
LOGIN — preview (next start)
{
  "msg": "login",
  "imei": "862669460113133",
  "model": "WT-400M",
  "cid": "WCT",
  "type": "WM-4G XM",
  "hwver": "1.1",
  "swver": "1.1.1",
  "mdbver": "1.0",
  "time": "20260708145020",
  "sig": 26,
  "nw": "IND airtel airtel"
}
LOGIN — last actually emitted
— no login emitted yet —
DATA — preview (2 packets on next tick)
{
  "data": {
    "imei": "862669460113133",
    "uid": 1,
    "dtm": "20260708145020",
    "seq": 3949,
    "sig": 26,
    "msg": "log",
    "modbus": [
      {
        "sid": 1,
        "stat": 0,
        "rcnt": 30,
        "reg1": 95.94,
        "reg2": -4.0,
        "reg3": 114,
        "reg4": 110,
        "reg5": 111,
        "reg6": 106,
        "reg7": 114,
        "reg8": 106,
        "reg9": 108,
        "reg10": 112,
        "V1": 0.0,
        "V2": 0.0,
        "V3": 0.0,
        "I1": 0.0,
        "I2": 0.0,
        "I3": 0.0,
        "KW": 0.0,
        "KVA": 0.0,
        "KVAR": 0.0,
        "PF": 0.0,
        "KWH": 0.0,
        "F": 0.0,
        "COST": 0.0,
        "BALANCE": 0.0,
        "TEMP_C": 0.0,
        "SETPOINT_C": 0.0,
        "DOOR": 0,
        "COMP_ON": 0,
        "RUNTIME_H": 0.0,
        "DOOR_OPEN_S": 0
      }
    ]
  }
}

----- next packet -----

{
  "data": {
    "imei": "862669460113133",
    "uid": 1,
    "dtm": "20260708145020",
    "seq": 3950,
    "sig": 26,
    "msg": "log",
    "modbus": [
      {
        "sid": 2,
        "stat": 0,
        "rcnt": 28,
        "reg1": 95.23,
        "reg2": -4.0,
        "reg3": 105,
        "reg4": 113,
        "reg5": 102,
        "reg6": 102,
        "reg7": 108,
        "reg8": 106,
        "reg9": 106,
        "reg10": 101,
        "TEMP_C": 0.0,
        "SETPOINT_C": 0.0,
        "DOOR": 0,
        "COMP_ON": 0,
        "KW": 0.0,
        "KWH": 0.0,
        "RUNTIME_H": 0.0,
        "DOOR_OPEN_S": 0,
        "HUMIDITY": 0.0,
        "DEW_POINT": 0.0,
        "FLOW_LPM": 0.0,
        "TOTAL_KL": 0.0,
        "TANK_LEVEL_PCT": 0.0,
        "TANK_LEVEL_L": 0.0,
        "PRESSURE_BAR": 0.0,
        "PUMP_ON": 0,
        "INLET_OPEN": 0,
        "OPEN_VALVES": 0
      }
    ]
  }
}
DATA — last actually emitted
— click Test Emit (modbus) to see —

Live log (latest 80 · click a row to see payload · scroll)

tsdirkindsummary